Interviews Best Engineering Interviews:Aeronautical EngineeringAgricultural EngineeringApplied EngineeringAssociate EngineeringAutomobile EngineeringBio EngineeringBiomedical EngineerBiomedical EngineeringBuilding Services EngineeringCAD/CAE EngineerChemical EngineeringCivil EngineeringDAE Knitting EngineersDeputy Chief Financial OfficerDesktop EngineerDiesel MechanicElectrical EngineeringElectronics CommunicationsElectronics EngineeringEmbedded Software EngineerEnergy EngineeringEnergy Oil GasEngineeringGalvanizing EngineerIndustrial EngineeringInstrumentation EngineeringLaptop RepairerMachine Learning EngineerMachine OperatorMarine EngineeringMechanical EngineeringMechatronics EngineeringNetwork EngineerNuclear EngineeringPetroleum EngineeringPlant Reliability EngineerPlumberPre EngineeringProduction EngineerRF EngineerSystem EngineeringTextile Engineer
Copyright © 2018. All Rights Reserved
Chemical Engineering Interview Question:
How can you determine the largest impeller that a pump can handle?
Submitted by: AdministratorThe motor amperage should be measured in the field with the pump discharge valve wide open. Subtract about 10% from the pumps maximum rated amperage. Then the maximum impeller size can be determined from A2 = A1 (d2/d1)3 A2 = Maximum amperage minus 10% A1 = Current operating amperage d2 = Maximum impeller diameter d1 = Current impeller diameter