How can you estimate the efficiency of a pump?
Submitted by: AdministratorThe following method, developed by M.W. Kellogg, gives results within 3.5% of most manufacturers' curves. Eff % = 80-0.2855H+3.78x10-4HF-2.23x10-7HF2+5.39x10-4H2-6.39x10-7H2F+4.0x10-10H2F2 H = Developed head, ft F = Flow in GPM (gallons per minute) Applicable for heads from 50 to 300 ft and flows from 100 to 1000 GPM
Submitted by: Administrator
Submitted by: Administrator
Read Online Chemical Engineering Job Interview Questions And Answers
Top Chemical Engineering Questions
☺ | What is a good estimate for the absolute roughness for epoxy lined carbon steel pipe? |
☺ | For a heat exchanger, will the overall heat transfer coefficient increase along with an increase in LMTD (log mean temperature difference) around the unit? |
☺ | What is the method of determining maximum differential pressure during hydro testing of shell and tube heat exchangers? |
☺ | What is a "saltation velocity" and how is it used in designing pneumatic conveying systems? |
☺ | Why is post-weld heat treatment (stress relieving) sometimes necessary for welded vessels? |